Ravi Gupta
More ideas from Ravi
DIGIPOINT Extremely sensitive acoustic, magnetic sensor. Coincidence figure readout. Built to withstand rugged field conditions. Headphones for acoustic signal. Proportional signal on large L.C.D. Screen for magnetic and acoustic indication. Light weight receiver. Easy to use.

DIGIPOINT Extremely sensitive acoustic, magnetic sensor. Coincidence figure readout. Built to withstand rugged field conditions. Headphones for acoustic signal. Proportional signal on large L.C.D. Screen for magnetic and acoustic indication. Light weight receiver. Easy to use.

MURRAYLOOP T-1502 Portable, Battery operated. For pre-location of low & high resistance constant leakage fault. When used with suitable high voltage DC supply. Suitable for constant leakage fault up to 5 K.V. DC. Gives reading in % of cable length. Accuracy up to 1% of fault distance. Null deflection by means of LED. Calibrated ten turn potentiometer.

MURRAYLOOP T-1502 Portable, Battery operated. For pre-location of low & high resistance constant leakage fault. When used with suitable high voltage DC supply. Suitable for constant leakage fault up to 5 K.V. DC. Gives reading in % of cable length. Accuracy up to 1% of fault distance. Null deflection by means of LED. Calibrated ten turn potentiometer.

Cable fault Locating Instruments:  Surge generator T-1020(8RLM),  Suitable for fault location in 440V to 11 KV Cables. High voltage testing up to 20 KV DC. Limited Burning Capability. 800 JOULES Energy on 5, 10, 20 KV Range. Inbuilt Reflectometer T-510 with LAPTOP for taking distance to the fault. Built in ARC Reflection Filter. Suitable as thumper required for pinpointing of fault. Compact small design, light weight.

Cable fault Locating Instruments: Surge generator T-1020(8RLM), Suitable for fault location in 440V to 11 KV Cables. High voltage testing up to 20 KV DC. Limited Burning Capability. 800 JOULES Energy on 5, 10, 20 KV Range. Inbuilt Reflectometer T-510 with LAPTOP for taking distance to the fault. Built in ARC Reflection Filter. Suitable as thumper required for pinpointing of fault. Compact small design, light weight.

CABLE IDENTIFICATION SET Mains/internal battery operated Pulse Transmitter giving 60 A impulse output. Hands held Pulse Receiver with 6 sensitivity ranges and center zero galvanometer. Robust Directional tongs having 105 mm internal diameter. Optionally bigger togs of 150 mm or 200 mm internal diameters can be provided to work successfully with the above system.

CABLE IDENTIFICATION SET Mains/internal battery operated Pulse Transmitter giving 60 A impulse output. Hands held Pulse Receiver with 6 sensitivity ranges and center zero galvanometer. Robust Directional tongs having 105 mm internal diameter. Optionally bigger togs of 150 mm or 200 mm internal diameters can be provided to work successfully with the above system.

CABLE IDENTIFICATION SET Mains/internal battery operated Pulse Transmitter giving 60 A impulse output. Hands held Pulse Receiver with 6 sensitivity ranges and center zero galvanometer. Robust Directional tongs having 105 mm internal diameter. Optionally bigger togs of 150 mm or 200 mm internal diameters can be provided to work successfully with the above system.

CABLE IDENTIFICATION SET Mains/internal battery operated Pulse Transmitter giving 60 A impulse output. Hands held Pulse Receiver with 6 sensitivity ranges and center zero galvanometer. Robust Directional tongs having 105 mm internal diameter. Optionally bigger togs of 150 mm or 200 mm internal diameters can be provided to work successfully with the above system.

CABLE IDENTIFICATION SET Mains/internal battery operated Pulse Transmitter giving 60 A impulse output. Hands held Pulse Receiver with 6 sensitivity ranges and center zero galvanometer. Robust Directional tongs having 105 mm internal diameter. Optionally bigger togs of 150 mm or 200 mm internal diameters can be provided to work successfully with the above system.

CABLE IDENTIFICATION SET Mains/internal battery operated Pulse Transmitter giving 60 A impulse output. Hands held Pulse Receiver with 6 sensitivity ranges and center zero galvanometer. Robust Directional tongs having 105 mm internal diameter. Optionally bigger togs of 150 mm or 200 mm internal diameters can be provided to work successfully with the above system.

MURRAYLOOP T-1502 Portable, Battery operated. For pre-location of low & high resistance constant leakage fault. When used with suitable high voltage DC supply. Suitable for constant leakage fault up to 5 K.V. DC. Gives reading in % of cable length. Accuracy up to 1% of fault distance. Null deflection by means of LED. Calibrated ten turn potentiometer.

MURRAYLOOP T-1502 Portable, Battery operated. For pre-location of low & high resistance constant leakage fault. When used with suitable high voltage DC supply. Suitable for constant leakage fault up to 5 K.V. DC. Gives reading in % of cable length. Accuracy up to 1% of fault distance. Null deflection by means of LED. Calibrated ten turn potentiometer.

DIGIPOINT Extremely sensitive acoustic, magnetic sensor. Coincidence figure readout. Built to withstand rugged field conditions. Headphones for acoustic signal. Proportional signal on large L.C.D. Screen for magnetic and acoustic indication. Light weight receiver. Easy to use.

DIGIPOINT Extremely sensitive acoustic, magnetic sensor. Coincidence figure readout. Built to withstand rugged field conditions. Headphones for acoustic signal. Proportional signal on large L.C.D. Screen for magnetic and acoustic indication. Light weight receiver. Easy to use.

Reflectometer T-510 Pulse Echo, Impulse Current & ARC Reflection Method. 10 Arc graphs + 1 reference graph for accurate & certain fault distance. Five waveforms for comparison. Easy to use Cursor. Large graphs storage capacity. Online support for experts reviews the fault graphs. Compact small, light weight design. Suitable to operate on mains (220-230/240 VAC, 45Hz up to 60 Hz) or portable generator.

Reflectometer T-510 Pulse Echo, Impulse Current & ARC Reflection Method. 10 Arc graphs + 1 reference graph for accurate & certain fault distance. Five waveforms for comparison. Easy to use Cursor. Large graphs storage capacity. Online support for experts reviews the fault graphs. Compact small, light weight design. Suitable to operate on mains (220-230/240 VAC, 45Hz up to 60 Hz) or portable generator.

Cable fault Locating Instruments:  Surge generator T-1020(8RLM),  Suitable for fault location in 440V to 11 KV Cables. High voltage testing up to 20 KV DC. Limited Burning Capability. 800 JOULES Energy on 5, 10, 20 KV Range. Inbuilt Reflectometer T-510 with LAPTOP for taking distance to the fault. Built in ARC Reflection Filter. Suitable as thumper required for pinpointing of fault. Compact small design, light weight.

Cable fault Locating Instruments: Surge generator T-1020(8RLM), Suitable for fault location in 440V to 11 KV Cables. High voltage testing up to 20 KV DC. Limited Burning Capability. 800 JOULES Energy on 5, 10, 20 KV Range. Inbuilt Reflectometer T-510 with LAPTOP for taking distance to the fault. Built in ARC Reflection Filter. Suitable as thumper required for pinpointing of fault. Compact small design, light weight.